| CORPORATE
DESCRIPTION:
Polymedco
Inc., is one of the leading marketing and distribution companies in the
clinical laboratory marketplace. Since the company’s inception in
1980, Polymedco has evolved over the years into a highly skilled and
successful marketing and sales organization. During the past 5 years, Polymedco has increased sales an impressive 400% and expanded its sales
force from 12 to over 50 representatives.
In
July of 1998, Polymedco purchased Bard Diagnostic Sciences (renamed
Alidex, Inc.), a diagnostic subsidiary of C.R. Bard. With
this addition, Polymedco maintains an ISO 9001 manufacturing and
research facility located in Redmond, Washington. |
 |
 |
 |
Poly
stat®
Point of Care Tests |
SPOTCHEM EZ™
chemistry analyzer |
Nyocard
Reader |
|
|
Poly
stat® Point of Care Tests
Waived and Moderately Complex cassette tests for: hCG,
Mono,
H. Pylori and Strep
A; Dipstick
tests for: hCG and Strep A
Products:
|
 |
| Poly
stat Strep A Strip Kit |
Back
to top
|
 |
CLIA
Classification |
Sample |
CPT
Code |
Methodology |
Sample
Volume |
Time
To Result |
Reported
Result |
MSDS
Sheet |
| STR25 |
Waived |
throat
swab |
87880 |
lateral
flow |
- |
5
min. |
pos/neg |
See
attached |
|
| Poly
stat hCG 3 Line Kit |
Back
to top
|
 |
CLIA
Classification |
Sample |
CPT
Code |
Methodology |
Sample
Volume |
Time
To Result |
Reported
Result |
MSDS
Sheet |
| HCG25 |
Waived |
Urine |
81025 |
lateral
flow |
0.2
ml |
4
min. |
pos/neg |
See
attached |
| HCG25M |
Moderately
Complex |
Urine
or Serum |
84703 |
lateral
flow |
0.2
ml |
5
min. |
pos/neg |
See
attached |
|
| Poly
stat hCG 2 Line Kit |
Back
to top
|
 |
CLIA
Classification |
Sample |
CPT
Code |
Methodology |
Sample
Volume |
Time
To Result |
Reported
Result |
MSDS
Sheet |
| HG25 |
Waived |
Urine |
81025 |
lateral
flow |
5
drops |
4
min. |
pos/neg |
See
attached |
| HG25M |
Moderately
Complex |
Urine
or Serum |
84703 |
lateral
flow |
5
drops |
4
min. |
pos/neg |
See
attached |
|
| Poly
stat Mono Kit |
Back
to top
|
 |
CLIA
Classification |
Sample |
CPT
Code |
Methodology |
Sample
Volume |
Time
To Result |
Reported
Result |
MSDS
Sheet |
| MON25 |
Waived |
Whole
Blood |
86308 |
lateral
flow |
40
microliters |
5
min. |
pos/neg |
See
attached |
| MON25M |
Moderately
Complex |
Whole
Blood, Serum, or Plasma |
86308 |
lateral
flow |
40
microliters whole blood, 20 microliters serum or plasma |
5
min. |
pos/neg |
See
attached |
|
| Poly
stat Strep A Cassette Kit |
Back
to top
|
 |
CLIA
Classification |
Sample |
CPT
Code |
Methodology |
Sample
Volume |
Time
To Result |
Reported
Result |
MSDS
Sheet |
| STR20 |
Moderately
Complex |
throat
swab |
87880 |
lateral
flow |
- |
5
min. |
pos/neg |
See
attached |
|
| Poly
stat H Pylori Kit |
Back
to top
|
 |
CLIA
Classification |
Sample |
CPT
Code |
Methodology |
Sample
Volume |
Time
To Result |
Reported
Result |
MSDS
Sheet |
| HPY25 |
Waived |
Whole
Blood |
86318 |
lateral
flow |
40
microliters |
5
min. |
pos/neg |
See
attached |
| HPY25M |
Moderately
Complex |
Whole
Blood, Serum, or Plasma |
86318 |
lateral
flow |
40
microliters whole blood, 20 microliters serum or plasma |
5
min. |
pos/neg |
See
attached |
|
SPOTCHEM EZ™
chemistry analyzer
SPOTCHEM EZis a small bench
top chemistry analyzer that utilizes dry chemistry technology.
Testing is performed on reagent strips with results available within
8 - 15 minutes. Maximum throughput is 48 tests per hour. The system
accepts whole blood samples. The instrument is calibrated
automatically with the swipe of a magnetic card. |
 |
| At the
conclusion of the testing, results are available on the SPOTCHEMtm
EZ printer or downloaded via LIS system. SPOTCHEMtm EZ is ideally
suited for small laboratories that desire an easy to use analyzer
with a small footprint and limited maintenance requirements.
|
|
|
SPECIFICATIONS |
|
Size: |
Width 13.5"
x depth 8" x height 6.5" |
|
Data Transfer Capability: |
6 pin cable
provided |
|
Specifications: |
No waste or
water lines required |
|
TEST KIT REQUIREMENTS |
|
Test Kit(s) Name: |
Lipid
Panel, Cholesterol, HDL, Triglycerides, Glucose, Fructosamine,
ALT, AST, ALP*, GGT*, LDH*, CPK*, AMY*, ALB*, BUN, T. BIL*,
CA, T. PRO*, CRE*, IP*, MG, UA*, PANEL 1 BMP* (BUN,GLU,CRE,CAL),PANEL
1, 2 CMP*(BUN,GLU,CRE,CAL)(ALB,ALP,T-BIL,ALT,AST) |
|
Test Menu: |
See test
kit names. |
|
CPT codes: |
Contact
Polymedco for specific information. |
|
Units in which test result
is reported:
|
Contact Polymedco for specific information. |
|
CLIA Classification: |
All
are moderately complex |
|
MSDS: |
Contact Polymedco for specific information. |
|
SOFTWARE REQUIREMENTS |
|
Download Capability:
|
Results
downloaded via cable. |
|
Reporting Features:
|
Results are
displayed on the LED screen once available. Once all the
tests per sample are completed, results are printed out via
the printer and also sent to the LIS. |
| LIS
Interface Capability:
|
RS232
port; 6 pin proprietary
cable included |
| Y2K
Compliant: |
Yes |
|
|
NycoCard™
READER II is a
Point of Care instrument, designed for rapid and reliable
measurements of all HgA1c, CRP, and Microalbumin*. With
NycoCardtm READER II, healthcare professionals in hospitals
and in general practice will obtain accurate, quantitative
results from all NycoCardtm tests. Easy to use. Rapid results. |
 |
| *
coming soon. |
|
|
SPECIFICATIONS |
|
Size: |
Width
7.5" x depth 5" x height 2" |
|
Data Transfer Capability: |
RS232
Port |
|
Specifications: |
No waste
or water lines required |
|
TEST KIT
REQUIREMENTS |
|
Test Kit(s) Name: |
HgbA1c,
CRP, and Microalbumin* |
|
Test Menu: |
See test
kit names. |
|
CPT codes: |
Contact
Polymedco for specific information. |
|
Units in which test result
is reported:
|
Contact Polymedco for specific information. |
|
CLIA Classification: |
All
are moderately complex |
|
Assay features: |
HgbA1c is
NGSP certified |
|
MSDS: |
Contact Polymedco for specific information. |
|
SOFTWARE
INFORMATION REQUIREMENTS |
|
Reporting Features:
|
Results
are displayed on the LED screen once available |
|
LIS Interface Capability:
|
Yes |
|
Y2K Compliant: |
Yes |
|
Screen captures: |
N/A |
|
|
|
Back
to top
|
|
|
[ Home | Search | Index | Feedback ]
Last updated:
06/22/2005
Questions or corrections: Webmaster